Primary Table: Use to sellect between Primary and Secondary fuel tables, this can be used in different conditions and have different Load references on the load axis, this is covered on the Load/RPM Axis configurations of this manual.
MAP/RPM: The table is structured with Manifold Absolute Pressure (MAP) on the vertical axis and RPM on the horizontal axis. Each cell represents a specific operating condition.The values on the axis, number of cells and the type of Variable to use for the Load can be changed on the Engine Configs- Load/RPM Settings
Values: Each cell contains a percentage value of VE, table has a precision of 0.024% and can accept values up to 1600%
Load/Store: Buttons to load settings from memory or store current settings. Useful for saving configurations or loading previously tuned settings.
Import Table: Allows importing pre-configured tables which can be useful for starting with a baseline or transferring settings between similar engines.
Auto Cursor: When checked, it might automatically move the cursor or highlight within the table based on current engine conditions.It allows you to know where the firmware is reading from in real time.
Selection: It's used to change several values at the same time, have a look at the RM Tuner quick guide video for more details.
% Correction: Provides quick adjustment options for the selected value in the table:
-5%
-1%
1%
5%
Custom: Allows for a custom percentage adjustment, with a current setting of 0%.