Many devices in a modern car already measure what you want: an EGT amplifier, a wideband controller, a dash with buttons, a keypad, a gearbox or a body module. Instead of wiring each sensor to the ECU again, the RM-Primis can read their values off the CAN bus. Up to 64 CAN input variables take a value from any CAN message, scale it, and use it as an exhaust temperature, show it live, or let its bits switch ECU functions such as a table switch or the traction control.
This page explains how a CAN input is set up and gives examples.
Open Setup → CAN bus → Input settings to set up each variable, and Input values to see all 64 live.
| Setting | What it does |
|---|---|
| Input variable number | Which of the 64 variables you are editing |
| Data type | 8, 16 or 32 bits, unsigned or signed, or Bitfields for a value made of single bits |
| Big-endian | The byte order: on for most-significant byte first (Motorola), off for least-significant first (Intel) |
| Address | Which of the 16 receive addresses (message IDs) the value comes from |
| Byte / Bit | Where in the message the value starts |
| Length | How many bits the value has |
| Multiply / Divide / Offset | Scale the raw number into real units: value = raw × Multiply ÷ Divide + Offset. Multiply must be greater than 0 |
| Use as | Makes the value one of the ECU's exhaust temperatures, EGT 1 to EGT 8 |
| Bit 1–3: Bit | Which bit of the value controls a function |
| Bit 1–3: Change | Direct (the bit on, the function on), Inverted, Toggle on rising or Toggle on falling (each press switches it) |
| Bit 1–3: Control | What the bit switches: the fuel, lambda, ignition, intake or exhaust VVT, or boost table set, the SD log, traction control, the A/C or the fan request |
Exhaust temperature from a CAN EGT amplifier. The amplifier sends each channel as a 16-bit value in 0.1 °C. Set the address to its message ID, Byte to the channel's first byte, Length 16, Data type 16 bits unsigned, Multiply 1, Divide 10, and Use as EGT 1. Repeat for each channel.
A map switch on a CAN keypad. The keypad sends a byte with one bit per button. Set Data type to Bitfields, then under Bit 1 choose the button's bit, Change Toggle on rising and Control Switch Fuel Table: each press of the button swaps the fuel table set. See Table switch.
Get the device's CAN documentation (or a DBC file) first: you need each value's message ID, start byte, length, byte order and scaling. Check the result on Input values against the device's own display.
Any device that sends its data on the same CAN bus at the same speed, as long as you know where each value is in its messages.
Yes: use Bitwise settings to let a bit of a CAN value switch the fuel, lambda, ignition, VVT or boost tables to their secondary set.