Most cars have a handful of things that just need switching on and off at the right moment: an intake flap that opens above 2000 rpm, a cooling fan, a purge valve, a water spray, a shift light, a nitrous arming relay, a warning lamp. Programmable outputs let you build each one yourself as a rule: choose an output, the condition that switches it, and how long it may stay on. No dedicated function needed.
This page explains how a rule works and walks through real examples.
Each of the 16 rules drives one output:
The Status column shows each rule live, ON or OFF, so you can watch your rules work.
Timing in detail.
| Setting | What it does |
|---|---|
| Delay | The rule must be true this long before the output switches on: a short delay stops it flickering |
| Limit: Minimum with a Time | Once on, the output stays on at least this long, even if the rule stops being true |
| Limit: Maximum with a Time | The output switches off after this long, even if the rule is still true. Useful for a pump that must not run forever |
A time of 0 disables the timing.
Open I/O → Inputs & outputs → Programmable outputs (see the menu on the Radiator fan and air conditioning page). All 16 rules are in one table.
The whole table, with condition 2 and the timing columns:
The rules in the pictures come from a running car:
| Rule | Output | Condition | What it does |
|---|---|---|---|
| FAN | High Side 3 | Coolant temperature ≥ 80 °C | A cooling fan switched straight from the coolant temperature |
| DISAs | High Side 2 | RPM ≥ 2000 | A BMW DISA intake flap: the intake manifold changes its runner length above 2000 rpm for more top-end power |
| VENTs | High Side 4 | Engine cycles after running > 100 AND MAP < 95 kPa | A purge or vent valve that only opens once the engine has been running for a moment and is not at full load |
More ideas:
| Function | Rule |
|---|---|
| Shift light | RPM ≥ 6800, active high, to a lamp |
| Intercooler water spray | Air temperature (IAT) > 50 °C AND TPS > 80 %, with a Maximum time of 10 s so the tank is not emptied in one go |
| Warning lamp for low voltage | Battery voltage < 12.0 V, with a 2 s Delay so a cranking dip does not light it |
| Second fuel pump | MAP > 150 kPa, with a Minimum time of 5 s so the pump does not cycle between gears |
Inputs used as conditions are treated as switches: on or off. Make sure each output you use is free and can drive the load: use a relay for anything more than a lamp or a small solenoid.
Sixteen rules, each driving one output.
Yes: combine condition 1 and condition 2 with AND, OR or XOR.
Yes: set the limit to Minimum with a time. The output then stays on at least that long.
Contact customer support at [email protected].
Related pages: Radiator fan and air conditioning · Special functions · Generic PWM outputs · Wiring diagram