While you tune, you need to see what the engine is doing right now: the engine speed and load that pick the table cell, the mixture against its target, the timing, the temperatures and whether anything is unhappy. RM-Tuner shows live data in three places: the live gauges along the bottom of every page, the Monitor list and the Dashboard of round gauges. You choose what each shows, and the Monitor can alarm when a value goes out of range.
Open Analyze → Monitor or Analyze → Dashboard. The live gauges at the bottom of the window are always there, on every page.
The Monitor is a list of live values, one per row, as many as you like. Select a row to choose what it shows and when it should alarm.
| Button | What it does |
|---|---|
| Add value / Insert above | Adds a row at the end or above the selected one |
| Move up / Move down | Reorders the rows |
| Blank line above | Adds a gap to group related values |
| Remove | Removes the selected row |
| Restore the standard list | Puts back RM-Tuner's own list |
| Gauge | Shows the selected value as a gauge |
Alarms. Give a value a low and a high alarm, for example coolant above 105 °C or oil pressure below 1 bar: RM-Tuner flags the value when it is out of range, so you notice a problem while you are looking at something else.
The Dashboard shows round gauges: easy to read at a glance from the driver's seat or across the dyno cell.
| Button | What it does |
|---|---|
| Add gauge | Adds a gauge |
| Remove / Change value... | Removes the selected gauge, or changes what it shows |
| Open in a window | Opens the dashboard in a window of its own, for a second screen |
| Size S / M / L | The gauges' size |
Click a gauge to change or remove it.
| Job | Show |
|---|---|
| Fuel tuning | RPM, MAP (or TPS in Alpha-N), lambda, lambda target, short-term trim, injector duty |
| Ignition tuning | RPM, MAP, ignition advance, knock retard, each cylinder's knock reading |
| Boost tuning | RPM, MAP, boost target, boost duty, lambda |
| Track day | RPM, coolant, oil pressure and temperature, lambda, battery voltage, with alarms |
Use the Datalog viewer to look back at what happened; the Monitor and Dashboard show what is happening now.
Yes: Open in a window opens it in its own window, which you can move to another screen.
Yes: give a Monitor row its alarm limits, and RM-Tuner flags the value when it is outside them.